Dynamic Hip Screw
Image

ASTM F 382 Standard Specification and Test Method for Metallic Bone Plates.





The DHS is indicated for the following fractures of the proximal femur:
- Intertrochanteric fractures.
- Subtrochanteric fractures.
- Fractures of the femoral neck.

Dynamic hip screw (DHS) or Sliding Screw Fixation is a type of orthopedic implant designed for fixation of certain types of hip fractures which allows controlled dynamic sliding of the femoral head component along the construct. The idea behind the dynamic compression is that the femoral head component is allowed to move along one plane; since bone responds to dynamic stresses, the native femur may undergo primary healing: cells join along boundaries, resulting in a robust joint which requires no remodeling.

Image

Stainless steel Dynamic Hip Screw is in accordance with ISO 5832-1 with angle 135° (For anatomic reduction, Less force working across sliding axis than higher angle plates and Prevents impaction) and available in 4- Hole configuration.

Hole                 4        5        6        8
Length (mm)     90      106    122     154
Image

DHS Nail is available in 13 lengths with DHS Lag and Compression Screw.

Image

Plate is attached to bone (distal fragment) by screws, Screw threads designed to allow optimum fracture compression and hold.

Image
Telescopic IM Nail
Image

ASTM E 290 Standard Test Methods for Bend Testing of Material for Ductility.




- Indicated for the situation that the bone is fragile and this fragility may elongates for a long period of time that requires long life support.
- Used for children who need multiple osteotomies.
- Fracture stabilization.
- Prevention of fracture during lengthening associated with external fixators.
- Different situation that require osteoporotic bone.
- Active infection.
- Irregular bone diameter or deformity that would prevent insertion of an IM device.

Image

Telescopic IM Nail is a new system designed for patients suffering from Osteogenesis Imperfecta (OI), skeletal dysplasia and other bone deformities. This product is proposed for growing skeleton that has some congenital or acquired anomalies who needs fixation in a long period of time with no necessity to change the device and can also be used concomitantly with external fixators in older children or short statured adults with limb length discrepancy. This rod has been designed for the femur, tibia and humerus. Telescopic nail consists of 2 parts: One profile bar (male nail), one profile tube (female nail); both made of stainless steel 316 LVM alloy (ISO 5832-1).

Image
High Tibial Osteotomy
Image
ASTM F 382
Standard Specification and Test Method for Metallic Bone Plates.


High tibial osteotomy (HTO) is an effective and established method in treating osteoarthritis of the medial compartment of the knee. The HTO system consists of plates, screws and spacer blocks. A typical construct is made up of a plate, 4 screws and a spacer block and locking screw.The plate has two screw holes distally and two adjacent screw holes proximally. The plate holes for the screws have a locking thread in them to ensure locking of the bone screws after insertion. The locking threads are angled to better place bone screws in bone stock. The proximal holes angle the screws divergently in the medial-lateral direction. The distal screw holes taper the screws distally. The plate features a central elongated channel that accepts a locking screw that connects the spacer block to the plate. The elongated slot allows for better positioning of the spacer block.
- Young, active patient (<50 years) in whom an arthroplasty would fail due to excessive wear.
- Uni-compartmental arthritis with varus deformity of the leg axis.
- Varus deformity < 10◦ with stable ligaments.
- Up to 65 years of age, depending on activity level.
- Minimum ROM 0-120◦.
- Preferably not significantly overweight.
- Extension deficits must be taken into account and compensated for in the osteotomy planning.
- Correction up to 10◦.
Titanium alloy HTO plate (Ti6Al4V) with ISO 5832-3, is available in one size (25×50 mm).
The plate has an anatomical bend in the proximal portion of 10°.
Image
Ti6Al4V Block screw with ISO 5832-3.
Image
Ti6Al4V Cancellous locking screw with ISO 5832-3 with ranges length from 34 to 78 mm.
Image
Ti6Al4V Cortical locking screw with ISO 5832-3 with ranges length from 22 to 55 mm.
Image
Ti6Al4V HTO cage (ISO5832-3) with various sizes (10, 12, 14, 16 mm).
Image
Image
Dynamic Compression Plate
Image

DCP plate is a metallic plate used in orthopedics for internal fixation of bone, typically after fractures. As the name implies, it is designed to exert dynamic pressure between the bone fragments to be transfixed. Dynamic compression is achieved either by attaching a tension device to a plate or by using a special dynamic compression plate.
- Placement of screw in neutral position without danger of distraction.
- All holes permit compression.
- Usage of two load screws in main fragment.
- Compression of several fragments individually in comminuted fractures.

DCP Plate is available in 2 narrow sizes and 1 broad size.

Hole                 2          3          4          5          6          7          8          9          10          12          14
Length (mm)    25         37        49        61        73         85        97        109         121        145        169


Image
Hole               2       3       4       5       6       7       8       9       10       11       12       13       14       15       16
Length (mm)   39     55     71      87     103    119    135     151     167     183     199     215     231     247     263


Image
Hole            4      5      6      7      8      9      10       11       12       13       14       15       16       17       18 
Length (mm)  71    87    103   119    135   151    167     183     199     215      231     247      263    279     295


Image
Locking Compression Plate
Image
ASTM F 382
Standard Specification and Test Method for Metallic Bone Plates.




LCP plate is a new development of the screw-plate system that allows the combination of standard plate technology and locking screws with angular stability. The special characteristics of the LCP are:
- Angular stability in combination with interfragmentary compression.
- In addition to conventional indications, the LCP is particularly well suited for the treatment of juxta-articular fractures and for osteoporotic bone, as well as for the use of percutaneous techniques.
- Incorporating features of LC-DCP (Limited Contact DCP).
- Uses non-locking and/or locking head screws (LHS).LCP Plate is available in 2 narrow sizes and 1 broad size.
Hole                2       3       4       5       6       7       8       9       10       11       12
Length (mm)   33      46     56     72     85     98      111    124     137     150     163


Image
Hole              2      3      4      5      6      7      8      9     10     11     12     13     14     15     16
Length (mm)  34    52    70    88    106   124   142   160   178   196   214   232   250   263   286
Image
Hole              2      3      4      5      6      7      8      9     10     11     12     13     14     15     16
Length (mm)  34    52    70    88    106   124   142   160   178   196   214   232   250   263   286
Image
Cancellous Screws
Image
ASTM F 543
Standard Specification and Test Methods for Metallic Medical Bone Screws.





Stainless steel Cancellous screws are in accordance with ISO 5832-1.
Cancellous screws are available in full thread and partial thread




- Ø 6.5 mm, 16 mm thread, available in 14 lengths (length 25-90 mm).
- Ø 6.5 mm, 32 mm thread, available in 14 lengths (length 45-110 mm).
- Ø 6.5 mm, full threads, available in 19 lengths (20-110 mm).


Cortical Screws
Image
ASTM F 543
Standard Specification and Test Methods for Metallic Medical Bone Screws.




Stainless steel cortical screws are in accordance with ISO 5832-1.
These screws are full thread and available in 2 sizes.



- Ø 3.5 mm, available in 16 lengths (10-40 mm).




- Ø 4.5 mm, available in 26 lengths (14-70 mm).




Locking Screws
Image
ASTM F 543      
Standard Specification and Test Methods for Metallic Medical Bone Screws.



Stainless steel Locking screws are in accordance with ISO 5832-1.
These screws are available in 2 diameters.



- Ø 3.5 mm, available in 16 lengths (16-70 mm).




- Ø 5 mm, available in 18 lengths (20-54 mm).




Cannulated Screws
Image
ASTM F 543
Standard Specification and Test Methods for Metallic Medical Bone Screws.



Stainless steel Cannulated screws are in accordance with ISO 5832-1.
These screws are available in 16 mm and 32 mm thread.



- Ø 7 mm, 16 mm thread, available in 4 lengths (length 50-65 mm).
- Ø 7 mm, 32 mm thread, available in 4 lengths (length 50-65 mm).